Abstract

SRAM-based FPGA devices are irradiated by 60Co γ rays at various dose rates to investigate total dose effects and the evaluation method. The dependences of typical electrical parameters such as static power current, peak—peak value, and delay time on total dose are discussed. The experiment results show that the static power current of the devices reduces rapidly at room temperature (25 °C) and high temperature (80 °C) annealing after irradiation. When the device is irradiated at a low dose rate, the delay time and peak—peak value change unobviously with an increase in the accumulated dose. In contrast, the function parameters completely fail at 2.1 kGy(Si) when the dose rate increases to 0.71 Gy(Si)/s.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.