Abstract

This paper discusses the effect of ionizing radiation on two types of deformable MEMS mirrors. Little effect was observed in the technology that was based on electrostatic deflection, consistent with the structural design that does not contain insulators between the two sections. Significant changes in the operating characteristics were observed for the second type of mirror, which uses piezoelectric material for actuation. The mirrors required higher total dose levels before they were affected compared with MEMS accelerometers, which can be explained by the larger interelement spacing used in the mirror arrays.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.