Abstract

Massive alveolar lavage has been used clinically to remove materials accumulated in the alveoli. Recently, filling the lungs with oxygenated perfluorochemical (total liquid ventilation) has been investigated. However, effects of complete and prolonged filling of bilateral lungs with aqueous fluid, such as saline or Ringer's solution, has not been evaluated, although it is possible to sustain gas exchange without the natural lung by using extracorporeal circulation and an artificial lung (extracorporeal lung assist: ECLA). It is also not known whether the lung can recover gas exchange ability after prolonged fluid filling. Normal mongrel dogs were endotracheally intubated under general anesthesia and mechanically ventilated. After initiation of venoarterial ECLA, warmed lactated Ringer's solution was instilled into the lungs through the endotracheal tube, and the lungs were completely filled at a hydrostatic pressure of 15 cmH2O (fluid-filled group: group F). After the lungs were filled for 4 h, the fluid was drained and ventilation was re-instituted. ECLA, then mechanical ventilation was gradually weaned within 24 h after fluid drainage. In control group (group C), dogs were kept apneic for 4 h with their lungs inflated at an airway pressure of 15 cmH2O with air. Transient hypoxemia occurred during fluid filling but every dog could be weaned from ECLA and mechanical ventilation to spontaneous respiration. The average rate of fluid absorption from the lung during fluid filling was 4.2+/-1.8 ml kg(-1) h(-1). After fluid drainage and restart of mechanical ventilation, bilateral lungs were expanded and well aerated. Total static respiratory system compliance (static compliance) remained unchanged even after fluid filling, and the weight of the lung water did not increase significantly compared to that in group C. Total urine volume was significantly increased in group E Histologically, alveolar structures were preserved and no interstitial edema or bleeding was seen in either group. Complete filling of the bilateral lungs for 4 h with lactated Ringer's solution under ECLA causes no deterioration in gas exchange or static compliance in normal dogs, although transient hypoxemia occurs during fluid filling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.