Abstract

Comprehensive analysis of the starting period of inverter-fed large induction motors reveals that these motors are subjected to additional components of pulsating torsional torque. These torque pulsations may coincide with the natural torsional frequency of the large motor system and produce hazardous shaft torque oscillations. To alleviate the torsional toque problem and limit the motor starting current, a constant air-gap flux using slip frequency control scheme is proposed to operate the motor inverter. Simulation results show that the proposed scheme is capable of drastically reducing the torsional torque oscillations and limiting the motor line current to approximately 22% of its direct online starting value without prolonging its starting period.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.