Abstract

This study evaluated torsional moments on activation and deactivation in commercial, nickel-titanium wires that are intended for use in the initial phases of orthodontic treatment. Nine commercial, rectangular nickel-titanium wires (0.017 × 0.025 in) were tested in torsion. One wire was conventional nickel-titanium, and the others were superelastic nickel-titanium wires. The specimens were tested in a torsiometer for rotations between 10 and 40 degrees in activation and deactivation. Wires E27, RF and R had the highest moments during activation and deactivation, without evidence of the plateau typical of the superelastic effect. Plateaus of constant moment were observed for wires C27, C35, E35, MO, NS, and NI. Torsional moments varied among superelastic nickel-titanium wires, even with wires that had the same transition temperature range. Some superelastic wires had torsional moments that were comparable with conventional nickel-titanium wires. (Am J Orthod Dentofacial Orthop 2001;120:76-9)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.