Abstract

Low-frequency (sub-synchronous) oscillation effects in geared gas turbine units that lead to the shutdown of the units and to breakdown of the power system are examined. The reasons are complicated and depend on the operation of variable frequency drives and the design features of the gas turbine unit. Data from tests by the firm JSC “Diamekh 2000” are presented. This paper examines the features of oscillations in the reducing gear when resonant torsional oscillations are present in the drive sleeve. It is proposed that gas turbine units without, rather than with, gearing be used in isolated power systems for operation with a variable frequency drive and for maintaining the balance between the nonlinear and linear components of the load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call