Abstract

<p>Flanged cruciform steel columns are often used in heavy-duty industrial buildings, with high axial loads and buckling length, to effectively eliminate weak-axis flexural buckling. Consequently, torsional buckling often becomes the governing failure mode under compression. While the effectiveness of twisting and warping restraints has been extensively studied for lateral torsional buckling, much less research is available on torsional buckling restraints in cruciform members.</p><p>For this study various FEM-assisted linear elastic buckling analyses have been performed to assess the increase in torsional buckling resistance due to typical end connections as compared to ideal fork end conditions. Furthermore, it is shown that adding intermediate warping restraints is an effective means against torsional buckling. Finally, a simple design criterion is presented for their spacing and dimensions to effectively eliminate torsional buckling.</p>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.