Abstract
Collisions between structures due to seismic oscillations have been reported many times in literature as a common case of damage. Further it is quite usual seismically induced oscillations of a structure in a city center block of buildings to be partly restrained in lateral displacements and therefore torsional behavior to be introduced in the structure. Two different types of structural interaction may be defined: (a) Diaphragm-to-diaphragm collisions (Type A). (b) The floor levels of the two structures are different. Consequently during the seismic oscillations the diaphragms of the first one impact the columns of the other (Τype B or interstory pounding). In this work the cases of an 8-story reinforced concrete building that suffers pounding with an adjacent structure that has 1, 2, 3, 4, 5, 6, 7 or 8 stories are studied. Pounding occurs only in one (Case 1) or in two (Case 2) columns of the structures and since the other columns are free to move without restrictions a torsional behavior is introduced (asymmetric pounding). Moreover in Type B interaction these columns of the 8-story frame structure undergo impacts at a height equal to 2/3 of their deformable length from the diaphragms of the other structure. The influence of an initial distance between the two interacting structures on the torsion effect is investigated too. Nonlinear seismic step-by-step analyses are performed. More than two hundred pounding cases with torsional effect each one for three natural seismic excitations are studied. Results in terms of shear and ductility demands of the columns are presented and commented. Both types A and B yielded high torsional structural rotation. In interaction Type B it can be deduced from the cases under examination that the column that is endured the impact from the top floor of the other structure develops high shear demands that exceed the available capacity many times during the step-by-step seismic analysis. Moreover high ductility demands have been observed for this column. Finally it is concluded that for buildings that may undergo asymmetric pounding not taking it into account may lead under certain conditions to non-secure design or even critical situations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.