Harmonic torques in induction machines can be generated by spatial and time harmonics. Stator and rotor slotting, rotor eccentricity, and multiple armature reactions cause space harmonics. Time harmonics originate in the non-sinusoidal wave shape of the terminal voltage. In addition, the interaction of space and time harmonics may generate side-band frequency torques, which can be of integer, non-integer (inter, fractional), or sub-harmonic order h within the frequency range from 0 to 60 Hz - appearing within the fundamental torque characteristic near zero speed. This paper analyzes and computes harmonic torques of induction machines due to low-frequency (f h < 60 Hz) components of the terminal voltage/current. The analysis suggests that the amplitude of low-frequency voltage/current harmonics must be restricted to a few percentage of the fundamental voltage not to jeopardize the start-up of induction motors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.