Abstract

The paper proposes Direct Torque Control (DTC) of a five-phase induction motor drive with reduced torque ripple. The method presented here is the DTC Backstepping based on the classic DTC working with a constant switching frequency of the inverter. Another remarkable aspect is the complexity of the method proposed, both in the control unit of the inverter and in the number of correctors necessary for the control of the torque. The selection table and hysteresis have been eliminated. This method significantly improves the torque and flux oscillations and improves the dynamics of the drive by making it less sensitive to load torque disturbances. The proposed method is developed and designed using Matlab/SIMULINK to show the eectiveness and performances of the DTC-Backstepping.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.