Abstract
This work presents a Direct Torque Control (DTC) technique for a six-phase asymmetrical induction motor fed with a two-level six-phase inverter for torque ripple minimization. By increasing the levels in conventional torque hysteresis controller, high torque ripples (which is a major problem in basic DTC) can be minimized and dynamic torque response can be improved. But in practice, the inevitable delay existing in the implementation of hysteresis controllers will cause undesirable overshoot and undershoot in the torque response resulting in high ripples. Also, the torque decreasing rate is comparatively higher than that of torque increase which further boosts the torque ripples and degrades the steady-state performance. A five-level torque controller with modified output status is presented here by taking into account the above two limitations. The auxiliary subspace which is inherently present in a six-phase machine causing stator current distortion is also controlled by generating virtual voltage vectors. The resulting DTC drive is validated using MATLAB/Simulink software.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.