Abstract

We present a three-dimensional study of the torque transmitted between tile permanent magnets uniformly magnetized. All this study is based on the Coulombian model. The torque is calculated semianalytically by considering all the surface densities that appear on the tiles. In addition, no simplifying assumptions are done in the expressions given in this paper. Consequently, the evaluation of the torque is very accurate and allows us to show the drawbacks of using tile permanent magnets uniformly magnetized instead of using tile permanent magnets radially magnetized. Such an approach is useful because it allows us to realize easily parametric studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.