Abstract

A suction muffler used in a fluid machine has three functions: noise reduction; minimizing pressure drop and improving energy efficiency using acoustic effects. However, no method of suction muffler design considers all three of these functions concurrently. Therefore, in this study, we attempt to provide an integrated design method of a suction muffler in a fluid machine that considers all three functions. The topology optimization method for acoustic and fluid systems was applied to an integrated design. However, the interaction between fluid and acoustic was not considered. In addition, the acoustic input impedance of a suction muffler was used for a specific acoustical resonance frequency to improve the energy efficiency of a fluid machine. Finally, the sequential optimization method based on physical investigations was proposed to satisfy several design criteria. The proposed method was applied to the suction muffler in refrigerator׳s compressor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.