Abstract
Concentrations of platinum and several other trace elements have been measured exploiting a 50 × 50 μ proton beam for PIXE analysis. The thickness of a selective germanium absorber for the spectral resolution of platinum L β and selenium K α peaks optimized, taking into account the fluorescent X-rays excited in the absorber material. The measurements have been performed in the framework of a project on the assessment of the toxicity of cytostatic platinum compounds. The lateral distributions of platinum in human kidneys and in dog tissues were measured. The highest concentrations of platinum were seen in arterial walls, followed by glomeruli and tubules. Chronic kidney damage may be correlated to this pattern of retention.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.