Abstract

During osteoarticular reconstruction of the distal radius with the proximal fibula, congruity between the two articular surfaces is an important factor in determining the quality of the outcome. In this study, a three-dimensional model and a coordinate transformation algorithm were developed on computed tomography scanning. Articular surface matching was performed and parameters for the optimal position were determined quantitatively. The mean radii of best-fit spheres of the articular surfaces of the distal radius and proximal fibula were compared quantitatively. The radial inclination and volar tilt following reconstruction by an ipsilateral fibula graft, rather than the contralateral, best resembles the values of the native distal radius. Additionally, the ipsilateral fibula graft reconstructed a larger proportion of the distal radius articular surface than did the contralateral. The ipsilateral proximal fibula graft provides a better match for the reconstruction of the distal radius articular surface than the contralateral, and the optimal position for graft placement is quantitatively determined.