Abstract
IntroductionTopical airway anesthesia is known to improve tolerance and patient satisfaction during flexible bronchoscopy (FB). Lidocaine is commonly used, delivered as an atomized spray. The current study assesses safety and patient satisfaction for nasal anesthesia of a new atomization device during outpatient bronchoscopy in lung transplant recipients.MethodsUsing a prospective, non-blinded, cross-over design, patients enrolled between 01-10-2014 and 24-11-2014 received 2% lidocaine using the standard reusable nasal atomizer (CRNA). Those enrolled between 25-11-2014 and 30-01-2015, received a disposable intranasal mucosal atomization device (DIMAD). After each procedure, the treating physician, their assistant and the patient independently rated side-effects and satisfaction, basing their responses on visual analogue scales (VAS). At their next scheduled bronchoscopy during the study period, patients then received the alternative atomizer. Written consent was obtained prior to the first bronchoscopy, and the study approved by the institutional ethics committee.ResultsOf the 252 patients enrolled between 01-10-2014 and 30-01-2015, 80 (32%) received both atomizers. Physicians reported better efficacy (p = 0.001) and fewer side effects (p< = 0.001) for DIMAD in patients exposed to both procedures. Among patients with one visit, physicians and their assistants reported improved efficacy (p = 0.018, p = 0.002) and fewer side effects (p< = 0.001, p = 0.029) for the disposable atomizer, whereas patients reported no difference in efficacy or side effects (p = 0.72 and p = 0.20). No severe adverse events were noted. The cost of the reusable device was 4.08€ per procedure, compared to 3.70€ for the disposable device.DiscussionTopical nasal anesthesia via a disposable intranasal mucosal atomization device (DIMAD) offers comparable safety and patient comfort, compared to conventional reusable nasal atomizers (CRNA) in lung transplant recipients. Procedural costs were reduced by 0.34€ per procedure.Trial Registrationclinicaltrials.gov NCT02237651
Highlights
Topical airway anesthesia is known to improve tolerance and patient satisfaction during flexible bronchoscopy (FB)
Non-blinded, cross-over design, patients enrolled between 01-10-2014 and 24-11-2014 received 2% lidocaine using the standard reusable nasal atomizer (CRNA)
Of the 252 patients enrolled between 01-10-2014 and 30-01-2015, 80 (32%) received both atomizers
Summary
Topical airway anesthesia is known to improve tolerance and patient satisfaction during flexible bronchoscopy (FB). Lidocaine is commonly used, delivered as an atomized spray. The current study assesses safety and patient satisfaction for nasal anesthesia of a new atomization device during outpatient bronchoscopy in lung transplant recipients
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.