Abstract

Analyser-based phase-contrast imaging (ABPCI) is a highly sensitive phase-contrast imaging method that produces high-contrast images of weakly absorbing materials. However, it is only sensitive to phase gradient components lying in the diffraction plane of the analyser crystal [i.e. in one dimension (1-D)]. In order to accurately account for and measure phase effects produced by the wavefield-sample interaction, ABPCI and other 1-D phase-sensitive methods must achieve 2-D phase gradient sensitivity. An inclined geometry method was applied to a Laue geometry setup for X-ray ABPCI through rotation of the detector and object about the optical axis. This allowed this traditionally 1-D phase-sensitive phase-contrast method to possess 2-D phase gradient sensitivity. Tomographic datasets were acquired over 360° of a multi-material phantom with the detector and sample tilted by 8°. The real and imaginary parts of the refractive index were reconstructed for the phantom.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.