Abstract

The magnetron injection gun (MIG) is the most critical part of any gyrotron. Small tolerances in the manufacturing process and alignment of the subcomponents directly affect the electron beam quality and therefore the beam wave interaction. At the Karlsruhe Institute of Technology (KIT), an innovative new Inverse MIG (IMIG) is proposed for the European 2-MW 170-GHz coaxial-cavity gyrotronwhich is under the developmentand test at KIT. The design of the IMIG has been done under strict consideration of the gun design criteria published earlier. In order to find the maximum allowed tolerances of that IMIG which allows operation within the allowed gun design criteria, systematic theoretical studies have been done. Commonly used “conventional” MIGs have been shown that a small emitter, anode, and cathodemisalignment have a significant influence to the electron beam quality.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.