Abstract
The resistivity of copper interconnect metallization can be influenced by low levels of contaminant (Cl, S, etc.) resulting from the electrochemical deposition process. ToF-SIMS imaging was used to investigate the distribution of contamination in Cu grains. ToF-SIMS images of full sheet Cu samples were compared with images of Cu lines in patterned test structures. An ION-TOF ToF-SIMS V instrument was used to acquire the images, and the results using Ga and Bi sources are compared. Cs sputtering was used to remove the surface oxide layer and to enhance the emission of Cl − ions. Enhanced Cl − emission is seen at the grain boundaries in full sheet samples and differences in Cl − emission are observed for Cu lines of different widths.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.