BackgroundBone graft substitute such as calcium sulfate are frequently used as carrier material for local antimicrobial therapy in orthopedic surgery. This study aimed to assess the systemic absorption and disposition of tobramycin in patients treated with a tobramycin-laden bone graft substitute (Osteoset® T).MethodsNine blood samples were taken from 12 patients over 10 days after Osteoset® T surgical implantation. Tobramycin concentration was measured by fluorescence polarization. Population pharmacokinetic analysis was performed using NONMEM to assess the average value and variability (CV) of pharmacokinetic parameters. Bioavailability (F) was assessed by equating clearance (CL) with creatinine clearance (Cockcroft CLCr). Based on the final model, simulations with various doses and renal function levels were performed. (ClinicalTrials.gov number, NCT01938417).ResultsThe patients were 52 +/− 20 years old, their mean body weight was 73 +/− 17 kg and their mean CLCr was 119 +/− 55 mL/min. Either 10 g or 20 g Osteoset® T with 4% tobramycin sulfate was implanted in various sites. Concentration profiles remained low and consistent with absorption rate-limited first-order release, while showing important variability. With CL equated to CLCr, mean absorption rate constant (ka) was 0.06 h-1, F was 63% or 32% (CV 74%) for 10 and 20 g Osteoset® T respectively, and volume of distribution (V) was 16.6 L (CV 89%). Simulations predicted sustained high, potentially toxic concentrations with 10 g, 30 g and 50 g Osteoset® T for CLCr values below 10, 20 and 30 mL/min, respectively.ConclusionsOsteoset® T does not raise toxicity concerns in subjects without significant renal failure. The risk/benefit ratio might turn unfavorable in case of severe renal failure, even after standard dose implantation.

Highlights

  • Since the end of the sixties, bone cement such as polymethyl methacrylate (PMMA) and bone graft substitute such as calcium sulfate are frequently used as carrier material for local antimicrobial therapy in orthopedic surgery for osteomyelitis, infected arthroplasty, soft tissue infections or prophylaxis

  • Concentration profiles were consistent with a one compartement model with absorption rate-limited first-order release, while showing important variability

  • With CL equated to CLCr, mean estimated ka was 0.0603 h−1, volume of distribution 16.6 L (CV 89%) and F was 63% and 32% (CV 74%) in the 8 patients having received 10 g Osteoset® T and in the 4 patients having received 20 g, respectively

Read more

Summary

Introduction

Bone graft substitute such as calcium sulfate are frequently used as carrier material for local antimicrobial therapy in orthopedic surgery. This study aimed to assess the systemic absorption and disposition of tobramycin in patients treated with a tobramycin-laden bone graft substitute (Osteoset® T). Since the end of the sixties, bone cement such as polymethyl methacrylate (PMMA) and bone graft substitute such as calcium sulfate are frequently used as carrier material for local antimicrobial therapy in orthopedic surgery for osteomyelitis, infected arthroplasty, soft tissue infections or prophylaxis. The aim of this study was to develop a population PK model for tobramycin in patients treated with an active calcium sulfate bone substitute and to predict tobramycin systemic exposure under various dose and renal function levels

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.