Introduction: Correct positioning of total ankle arthroplasty (TAA) implants has been associated with superior clinical outcomes. However, the correlation between implant position and ankle motion is unclear. The objective of this study was to assess the effect of tibial component position on ankle kinematics during simulated gait. Methods: The stance phase of gait was simulated pre and post-TAA with 8 mid-tibia cadaveric specimens using a six-degrees-of-freedom robotic platform. Ankle kinematics were measured based on reflective markers. A fixed-bearing total ankle system (Salto Talaris, Integra LifeSciences) was used. Using reconstructed CT data, the 3D tibial component position relative to a standard ankle joint reference was characterized (Fig 1A). The effect of the tibial component position on absolute differences in ankle kinematics (pre/post TAA) was assessed using linear regression with a level of significance set to p = 0.05. Results: Differences in ankle joint kinematics were only identified in the transverse plane, where internal talar rotation was significantly increased following TAA compared with the native condition (Fig 1B). The medial position of TAA tibial components was positively associated with increased internal talar rotation (Fig 1C; β = 1.861 degrees/mm, R2 = 0.72, p = 0.008). Conclusion: This study suggests that a medial-lateral position of the tibial implant affects ankle kinematics. During operative procedures, the tibial component is usually positioned to preserve the bone stock of the medial and lateral malleolus. However, little attention is given to the position of the implant in relation to the center of the tibial axis. This finding could have clinical implications for techniques.

Highlights

  • Resumo Introdução: O posicionamento correto dos implantes de artroplastia total do tornozelo (ATT) tem sido associado a resultados clínicos superiores

  • Utilizando dados de TC reconstruídos, caracterizou-se a posição dos componentes tibiais tridimensionais em relação a uma referência padrão da articulação do tornozelo (Fig. 1A)

  • Palavras-chave: Artroplastia de substituição do tornozelo; Simulação de marcha; Posição do componente; Cinemática do tornozelo; Artrite do tornozelo

Read more

Summary

Introduction

Resumo Introdução: O posicionamento correto dos implantes de artroplastia total do tornozelo (ATT) tem sido associado a resultados clínicos superiores. Influência da posição do componente tibial na cinemática alterada após artroplastia total do tornozelo durante a marcha simulada Guilherme Honda Saito1, Daniel Sturnick1, Jonathan Deland1, Scott Ellis1, Constantine Demetracopoulos1 1. Hospital for Special Surgery, Nova York, EUA.

Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call