Abstract

We aim to evaluate the safety and feasibility of novel elbow biopsy forceps with a prebent head for sampling biliary strictures in our institution. A total of 24 patients (15 males and 9 females) with biliary stricture who underwent biliary biopsy during endoscopic retrograde cholangiopancreatography (ERCP) using novel elbow biopsy forceps from June 2019 to August 2020 were retrospectively included. The novel biopsy forceps had a head angulation of 30 degrees and were able to cannulate the bile duct and approach the biliary strictures easily to obtain adequate samples. The technical success rate, incidence of adverse events, and consistency of pathological and surgical specimens were assessed. This device was used successfully in all patients. A total of 52 biopsy specimens were obtained from 24 patients, and all specimens could be used for histopathological examination. Seventeen patients were diagnosed with malignancy based on biopsies, and all of them underwent surgical treatment. The histopathological findings of the biopsy specimens were in accordance with the postoperative pathology diagnoses. One of the seven patients was diagnosed with a benign lesion that was proven to be malignant during surgical treatment in the follow-up period. Two patients experienced a single episode of acute pancreatitis and recovered shortly after appropriate treatment. No patients experienced biliary perforation or biliary bleeding. Biopsy using novel elbow forceps in patients with biliary stenosis is feasible and safe. The novel device and related biopsy technique may be widely applied for biliary disease differentiation.

Highlights

  • We aim to evaluate the safety and feasibility of novel elbow biopsy forceps with a prebent head for sampling biliary strictures in our institution

  • We introduced novel elbow biopsy forceps for biliary biopsy that are more flexible and easier to use for bile duct intubation

  • A total of 17 patients were diagnosed with malignant biliary stricture on biopsy

Read more

Summary

Introduction

We aim to evaluate the safety and feasibility of novel elbow biopsy forceps with a prebent head for sampling biliary strictures in our institution. The novel biopsy forceps had a head angulation of 30 degrees and were able to cannulate the bile duct and approach the biliary strictures to obtain adequate samples. The technical success rate, incidence of adverse events, and consistency of pathological and surgical specimens were assessed This device was used successfully in all patients. Histopathological examination is the gold standard for the diagnosis of biliary tract tumors; it is important to obtain adequate biopsy specimens from the bile duct. The sensitivity resulting from the use of biopsy forceps is higher than that of the biliary brushing technique, as ERCP is easy to perform and associated with few adverse e­ vents[6,7]. The main aim of this study was to evaluate the success rate and safety of this device and its related biopsy procedure

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call