Abstract
The tissue equivalence of solid state silicon detectors in proton radiation fields was determined to improve the radiation protection applications of silicon detectors in aviation and space missions. The study was performed by means of Geant4 simulations. Results are presented showing that a simple c( ~ 0.56) of linear dimensions is adequate to convert experimentally obtained microdosimetric energy deposition spectra in silicon to equivalent microdosimetric energy deposition spectra in water.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.