Pressure sensors embodied in very tiny packages are deployed in a wide range of advanced applications. Examples of applications range from industrial to altitude location services. They are also becoming increasingly pervasive in many other application fields, ranging from industrial to military to consumer. However, the inexpensive manufacturing technology of these sensors is strongly affected by environmental stresses, which ultimately affect their measurement accuracy in the form of variations in gain, hysteresis, and nonlinear responses. Thermal stresses are the main source of sensor behavior deviation. They are particularly insidious because even a few minutes of high temperature exposure can cause measurement drift for many days in the sensor responses. Therefore, conventional calibration techniques are challenged in their adequacy to achieve high accuracy and over the entire deployment life of the sensor. To manage this, several costly and time-consuming calibration procedures have to be performed. Machine learning (ML) techniques are known, supported by the universal approximation theorem, to provide effective data-driven solutions to the above problems. In this context, this paper addresses two case studies, corresponding to post-soldering thermal stresses and exposure to moderately high temperatures, for which two separate datasets have been built and 53 different tiny ML models (collected into a zoo) have been devised and compared. The ML zoo has been constructed with models such as artificial neural networks (ANN), random forest (RFR), and support vector regressors (SVR), able to predict the error introduced by the thermal drift and to compensate for the drift of the measurements. The models in the zoo also satisfy the memory, computational, and accuracy constraints associated with their deployment on resource-constrained embedded devices to be integrated at the edge. Quantitative results achieved by the zoo are reported and discussed, as well as their deployability on tiny micro-controllers. These results reveal the suitability of a tiny ML zoo for the long-term compensation of MEMS pressure sensors affected by drift in their measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.