Abstract

BackgroundTiming of hip fracture surgery for the internal fixation of an intracapsular fracture remains controversial and few studies to date have been able to determine the optimum time to surgery in minimizing osteonecrosis and non-union with intracapsular fractures after fixation. MethodsUsing a local hip fracture database managed by the senior author over a 32 year period, those who underwent osteosynthesis following intracapsular fractures were assessed for risk of development of non-union and osteonecrosis. Multivariate regression analysis was performed focusing on factors that were predictive of complications. Patient demographics, time from injury to surgery, fixation method, fracture pattern and complications at one year were reported. The primary outcome was whether delay to surgery contributed to risk of complications, defined as non-union or osteonecrosis. Secondary outcomes assessed the contribution of other factors to these complications. Results2,366 patients were identified with an average age of 74.7 years and 66.5% were female. 1189 (50.3%) of fractures were displaced. 481 (20.3%) had a complication at one year following fixation. 78 (3.3%) were fixed by DHS, 6 (0.3%) by cephalomedullary nail, (1257) 53.1% by cannulated screws and 1025 (43.3%) by Targon® screw. Multivariate regression revealed no significant correlation between delay to surgery and complication rates (OR 0.99, 95% CI 0.99, 1.01, p = 0.55). Significant variables include female sex (OR 2.03, 95% CI 1.58, 2.62, p<0.0001), fracture displacement (OR 4.8, 95% CI 3.79, 6.14, p<0.0001), independent mobility (OR 0.64, 95% CI 0.47, 0.87, p = 0.004) and use of Targon® screws compared to parallel screws (OR 0.61, 95% CI 0.48, 0.76, p<0.0001). ConclusionsOur study demonstrates no relationship between timing of surgery for fixation of intracapsular fracture and complication rates. Female sex and fracture displacement increased risk of complications whereas independent mobility and use of Targon® screw device in comparison to parallel screws were protective against non-union but not avascular necrosis.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.