The proposed Hall D detector at Jefferson Lab will have a time-of-flight detector composed of long and narrow scintillator bars. We have evaluated the time resolution of two bar prototypes in particle beams at the Institute for High Energy Physics in Protvino, Russia. The bars are 2.0 m long and have square cross-sections of size 2.5 and 5.0 cm 2 . In this paper, we present results on how the time resolution of each of these bars depends on the entry position of the beam into the scintillator, on the material used for scintillator wrapping and on the phototube used for the readout.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.