Abstract
Thermal techniques have matured for the nondestructive characterization of the internal structure of opaque solids in recent years. While CW-modulated thermal wave imaging techniques have proven applicable to the inspection of many types of structures, difficulties arise when the layers are thick or have low thermal diffusivity. The depth, l, into the specimen which can be probed is approximately one thermal diffusion length, δ = (2α/ω)l/2 where α is the thermal diffusivity and ω is the angular modulation frequency. When l/δ is large because of a low thermal diffusivity, the modulation frequency must be lowered to allow the full thickness of the structure to be examined. As the modulation frequency is decreased, the dwell time required at each point for construction of an image by a point-scanning technique increases as do the data acquisition times. For low diffusivity materials, the data acquisition times are too long for thermal wave imaging to be a feasible routine inspection technique.
Submitted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.