Abstract
Pulsed eddy current (PEC) nondestructive testing differs from conventional eddy current techniques in that the probe coil is excited by a pulse, rather than continuous excitation at a single frequency. Reviews of early work on pulsed eddy currents are given by Waidelich1 and by Renkin.2 Pulsed excitation causes the propagation of a highly attenuated traveling wave, which is governed by the diffusion equation.3 The diffusive propagation of the eddy current pulse results in spatial broadening and a delay, or travel time, proportional to the square of the distance traveled. It was realized in early work on pulsed eddy current systems that this time dependence offered certain advantages over conventional eddy currents.4 In the current study we demonstrate the ability of a prototype pulsed eddy current instrument, described elsewhere,5,6 to take advantage of this time dependence to discriminate flaws from such interfering signals as probe liftoff, air gaps, and fasteners.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.