Abstract
In this paper, a procedure is proposed to computer simulate the electronic noise of ionizing-radiation spectrometers. The viewpoint of the simulator is the output of the preamplifier, with or without an anti-aliasing filter, just in front of the ADC. Examples are given for the case of segmented high purity Germanium detectors (HPGe). The method makes use of the fractional calculus basics. A software procedure provides the noisy waveform as a function of the fundamental electrical-physical parameters of the system, including: detector capacitance, detector leakage current, feedback resistor, 1/f-noise coefficient of the input transistor, temperature of the preamplifier input devices. The ADC quantization noise is also included in the simulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.