Abstract
Transient operation of a co-current heat exchanger is analyzed in this paper, using a new predictive formulation for laminar and turbulent flows with mass discharge from the heat exchanger. The model includes time-varying mass discharge due to pressure regulated gas outflow. The temperature variations of the working fluid, heating fluid and the wall are predicted and validated against past data. It is found that the temperature of the working fluid rises sharply to a peak and then gradually decreases over time, due to mass discharge effects. The wall temperature decreases exponentially, and the temperature of the heating fluid falls sharply, and then gradually decreases. A benchmark case of a step change in the mass flow rate of the incoming fluid is analyzed and compared against past data for validation, after which results are presented and discussed for transient step changes of the incoming mass flow rate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.