Abstract

We have applied the standard wavelet and the adaptive wavelet transform algorithms to the record of the Central England Temperature (CET) from 1659–1990. Peaks in the CET spectra include 7.5±1.0 yr, 14.4±1.0 yr, 23.5±2.0 yr, as well as a previously unreported variation at 102±15 yr. Our wavelet analysis of CET agrees with previous results from Singular Spectrum Analysis (SSA) by Plaut et al. [1995] and gives additional results of variability on longer timescales. The interdecadal and century‐scale variability in CET is strongly dependent on the interval of analysis. Estimates of a data trend are also shown to be sensitive to the cutoff timescale of the filter. A cooling of ≈ 0.3°C during 1659–1720 is found relative to the temperatures during the 1800s. The complex time dependence of the actual data cautions against using model‐derived representations of natural variability on such long timescales.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.