Abstract

Time-reversal (TR) invariance of the wave equation in lossless transmission line (TL) is here introduced as an improvement for fault-detection techniques in wire networks. This new approach is applied to re∞ectometry in wire diagnosis. To test the e-ciency of this method, the reverse time algorithm simulated with FDTD (Finite Difierence Time Domain) is developed in a one dimension space. It uses a new signal processing and an adapted signal to the wire under test for diagnosing the fault in the wire. In addition, the interest of the convolution product between the incident signal and the output signal from this reverse time method will be also shown and applied in this paper. Through numerical simulations and experimental results measured on coaxial cable, the beneflts of this method have been illustrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.