Abstract

Capillary discharge plasmas can serve for recombination-pumped x-ray lasers. We present time-resolved x-ray spectra and density measurements of a nitrogen capillary discharge z-pinch plasma. We use a free-standing transmission grating spectrometer and a gated MCP camera. This is the first time both K-shell and L-shell line emission of the nitrogen plasma are recorded simultaneously. Comparison of the spectra with a 4-ion collisional-radiative atomic model, which accounts for opacity effects, shows that the plasma reaches a maximum temperature of kTe=75–85eV during the pinch, and adiabatically cools in less than 4ns. This is slightly less than the newly estimated goal temperature of 110eV. The fast cooling demonstrates the feasibility of a recombination-scheme laser in the nitrogen Hα line at 13.37nm, if higher plasma temperature is achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.