Abstract

Time-resolved Fourier-transform spectroscopy was applied to the study of the emission spectra of Cu vapours in a vacuum (10−2 Torr) produced in ablation of a Cu metal target by a high-repetition rate (1.0 kHz) pulsed nanosecond ArF laser (λ = 193 nm, output energy of 15 mJ). The time-resolved infrared emission spectrum of Cu was recorded in the 1800–3800 cm−1 spectral region with a resolution of 0.017 cm−1. The time profiles of the measured lines have maxima at 18–20 µs after a laser shot and display non-exponential decay with a decay time of 5–15 µs. This study reports 17 lines (uncertainty 0.0003–0.018 cm−1) of Cu I not previously observed. This results in seven newly-found levels and revised energy values for 11 known levels (uncertainty 0.01–0.03 cm−1). We also calculate transition probabilities and oscillator strengths for several transitions involving the reported Cu levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.