Abstract

Time-of-flight measurements of the photocurrent in thin organic semiconductor layers represent an effective way to extract charge carrier mobility. A common method to interpret the time-dependence of the photocurrent in these material systems assumes a position-independent electric field between two coplanar electrodes. In this letter, we compare time-dependence of the photocurrent, measured in the samples comprising thin layers of poly-3-hexylthiophene, with the Monte Carlo simulations. In the simulations, we have used both, a position-independent and a position-dependent electric field. We obtained a favorable agreement between the simulations and the measurements only in the case of position-dependent electric field. We demonstrate that the charge carrier mobility may be underestimated by more than one order of magnitude, if a position-independent electric field is used in the calculations of the mobility.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.