Abstract

In-service degradation of a pipe section is monitored in real time with torsional guided waves which can resolve 5% damage to the internal wall. We use a single permanently installed source–receiver pair as opposed to the current state-of-the-art sensor rings. There is no baseline subtraction requirement as a single reflection coefficient is derived by internal referencing of the time trace. Even with continuously operating pump vibration, there is enough acoustic signal for confident damage localization. Since pipelines wear out gradually in industrial installations, the acoustic footprint is similar to that previously determined in periodically damaged pipes. The reflective method can thus be applied successfully to monitor structural health in industrial pipelines during operation as opposed to the current state-of-the-art guided wave inspection approaches using near-weld reflection techniques along with disassembled and re-assembled sensor rings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.