As stress waves decay as they pass through the pile foundation system, it is extremely challenging for all nondestructive testing methods to evaluate the pile integrity of a shaft underneath a structure. In this study, time–frequency signal analysis (TFSA) is used for signal processing and adopted to interpret the pile integrity testing signal. An experimental case with pile lengths of 58m with caps, were tested by the low strain sonic echo method. Traditional time domain analyses can not identify the pile tip response signals 58m lengths. After time-history curves are transformed into a time–frequency domain distribution, the results indicate the pile tip can be located more easily and clearly than the traditional time-domain analyses of pile integrity testing allowed for.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.