Abstract

Technical and pure grades of the combustibles heptane and dodecane were used in a series of small-scale fire tests conducted in a 1m3 compartment that was mechanically ventilated at 5 and 8 air changes per hour (ACH). Combustible mass loss rates, soot mass concentrations, soot size distributions, several gas species concentrations, and compartment temperatures were measured during the fire. Results for the two pure-grade hydrocarbons were compared with results obtained for their respective technical grades. Technical-grade dodecane produced the highest soot emissions; pure n-heptane produced the lowest. Soot size distributions of all four combustibles attained a steady profile whose modal diameter was about 200nm. Underventilated fires showed higher carbon monoxide yields than soot yields. Both compartment ventilation rates produced similar results, although the fire self-extinguished earlier for 5ACH.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.