Abstract

Time-dependent passive infrared thermography (td-PIRT) is an inspection technique that can be used to detect delamination. td-PIRT was used to inspect two buildings in Lisbon (Portugal) with adhered ceramic cladding to evaluate its potential to detect delamination problems in such claddings, which is a common problem and has safety risks. The td-PIRT data were analysed quantitatively by means of simple image subtraction (SIS), nonnegative matrix factorisation (NMF), and principal component analysis (PCA). Comparative evaluations showed that td-PIRT has a great potential to detect delamination problems in adhered ceramic cladding, depending on the analysis method selected. PCA and NMF were found to be efficient methods because of their good, consistent performance in revealing defective areas.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.