Time dependent aerosol particle deposition due to gravitational settling is examined for steady laminar flow in ducts of different cross sections and flow profiles. Analytic and some numerical calculations based on the analysis of limiting particle trajectories are used to determine the deposition efficiencies and penetrations as functions of duct length and time. Both efficiencies and penetrations are found to be strongly time dependent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.