Abstract

There is growing interest in the effect of diffusion time on apparent diffusion coefficient (ADC) values in cancers; however, little evidence exists regarding its utility to differentiate malignant from benign head and neck tumors. To investigate the utility of ADC value changes in distinguishing between malignant and benign head and neck tumors using the different diffusion times obtained from oscillating gradient spin-echo (OGSE) and pulsed gradient spin-echo (PGSE) MRI sequences. Prospective. Thirty-one consecutive patients with suspected head and neck tumors and a phantom. 3T MRI with diffusion-weighted imaging (DWI) using OGSE (effective diffusion time: 4.3 msec) and PGSE (effective diffusion time: 82.6 msec) sequences and b-values of 0 and 700 s/mm2 . ADC values using OGSE (ADCOGSE ) and PGSE (ADCPGSE ) and relative ADC value changes between ADCOGSE and ADCPGSE . Wilcoxon test, Mann-Whitney test, and McNemar test. Relative ADC changes for each polyvinylpyrrolidone (PVP) and water in the phantom between OGSE and PGSE sequences were small (relative ADC change within 0.6%). Malignant tumors had significantly smaller ADCOGSE and ADCPGSE values than benign tumors (P < 0.001 and < 0.0001, respectively). Significantly larger relative ADC changes were observed in malignant compared with benign head and neck tumors (P < 0.0001). ADCPGSE values were significantly lower than ADCOGSE values in both malignant and benign head and neck tumors (0.97 vs. 1.28 × 10-3 mm2 /s: P < 0.0001 and 1.93 vs. 1.99 × 10-3 mm2 /s: P = 0.0056, respectively). Relative ADC change and ADCPGSE tended to have higher diagnostic performance than ADCOGSE , with area under the curve (AUC) values of 0.97, 0.96, and 0.89, respectively. ADC values obtained using the PGSE sequence were lower than those obtained with OGSE. This difference was larger for malignant than benign tumors, suggesting differences in tissue structure (diffusion hindrance) or cell permeability, revealed by changes in diffusion time. The results underline the potential importance of reporting diffusion time for interpretation of head and neck diffusion MRI. 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:88-95.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call