Abstract
Time-average TV holography is widely used method for vibration measurement. The method generates speckle correlation time-averaged J0 fringes that can be used for full-field qualitative visualization of mode shapes at resonant frequencies of an object under harmonic excitation. In order to map the amplitudes of vibration, quantitative evaluation of the time-averaged fringe pattern is desired. A quantitative evaluation procedure based on the phase-shifting technique used in two beam interferometry has also been adopted for this application with some modification. The existing procedure requires a large number of frames to be recorded for implementation. We propose a procedure that will reduce the number of frames required for the analysis. The TV holographic system used and the experimental results obtained with it on an edge-clamped, sinusoidally excited square aluminium plate sample are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.