Abstract

Background:Nonanatomic graft placement is a frequent cause of anterior cruciate ligament reconstruction (ACLR) failure, and it can be attributed to either tibial or femoral tunnel malposition. To describe tibial tunnel placement in ACLR, we used EOS, a low-dose biplanar stereoradiographic imaging modality, to create a comprehensive grid that combines anteroposterior (AP) and mediolateral (ML) coordinates.Purpose:To (1) validate the automated grid generated from EOS imaging and (2) compare the results with optimal tibial tunnel placement.Study Design:Descriptive laboratory study.Methods:Using EOS, 3-dimensional models were created of the knees of 37 patients who had undergone ACLR. From the most medial, lateral, anterior, and posterior points on the tibial plateau of the EOS 3-dimensional model for each patient, an automated and personalized grid was generated from 2 independent observers’ series of reconstructions. To validate this grid, each observer also manually measured the ML and AP distances, the medial proximal tibial angle (MPTA), and the tibial slope for each patient. The ideal tibial tunnel placement, as described in the literature, was compared with the actual tibial tunnel grid coordinates of each patient.Results:The automated grid metrics for observer 1 gave a mean (95% CI) AP depth of 54.7 mm (53.4-55.9), ML width of 75.0 mm (73.3-76.6), MPTA of 84.9° (83.7-86.0), and slope of 7.2° (5.4-9.0). The differences with corresponding manual measurements were means (95% CIs) of 2.4 mm (1.4-3.4 mm), 0.5 mm (–1.3 to 2.2 mm), 1.2° (–0.4° to 2.9°), and –0.4° (–2.1° to 1.2°), respectively. The correlation between automated and manual measurements was r = 0.78 for the AP depth, r = 0.68 for the ML width, r = 0.18 for the MPTA, and r = 0.44 for the slope. The center of the actual tibial aperture on the plateau was a mean of 5.5 mm (95% CI, 4.8-6.1 mm) away from the referenced anatomic position, with a tendency toward more medial placement.Conclusion:The automated grid created using biplanar stereoradiographic imaging provided a novel, precise, and reproducible description of the tibial tunnel placement in ACLR.Clinical Relevance:This technique can be used during preoperative planning, intraoperative guidance, and postoperative evaluation of tibial tunnel placement in ACLR.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.