Abstract
There are several theoretic advantages of using intramedullary rod fixation for tibial osteotomy fixation. We performed a retrospective review of patients who were treated with a mid-diaphyseal osteotomy of the tibia fixed with an intramedullary rod for isolated, symptomatic tibial torsion. Forty patients (59 tibias) were included in the study and were followed for a minimum of 12 months or until rod removal (average follow-up 22.6 months). Major complication rate was 8.5%, which is comparable to alternative methods of fixation. We believe that intramedullary rods are a safe alternative for fixation of tibial rotational osteotomy in patients with physeal closure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.