The effect of trace addition of Ti on the corrosion behavior of Sn–9Zn (wt.%) solder alloy in NaCl solution was investigated using polarization and electrochemical impedance spectroscopy techniques. It is found that the corrosion resistance of Sn–9Zn alloy can be significantly enhanced by adding 0.05wt.% of Ti, evidenced by much lower corrosion current density, lower passive current density and higher impedance. Such enhancement results from the refinement of Zn-rich precipitates within the microstructure, which is conducive to forming a relatively more protective passive film on the surface of the modified alloy. This would be an important finding in the design of novel Sn–Zn solder alloys in electronic assemblies operating under aggressive conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.