Abstract
This study proposes a new AC/AC phase hopping frequency conversion method based on the analyses of the disadvantages of the conventional cosine wave-crossing method. The advantages of this new method include no circulating current, no dead time, and an output frequency close to the power frequency. This study also introduces the basic principles of the phase hopping method and analyzes these principles combined with the voltage phase-changing comparison to that of the cosine wave-crossing method. The phase hopping principles are used to analyze the generation of thyristor trigger pulses, including the generation time and duration. A simulation is conducted in MATLAB, and the simulation output waveform and harmonic analysis results are then obtained. The proposed approach is verified on an experimental platform. Consequently, the results are in good agreement with those of the theoretical and simulation analyses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.