Abstract
Traumatic amputation of the thumb at the proximal phalanx or the metacarpophalangeal joint can be treated by distraction lengthening depending on the location of the amputation, the patient's age, occupation and functional demands. We report the results of proximal phalanx lengthening in 5 patients using a semicircular ring-type external fixator device. This prototype was developed at our clinic in collaboration with a specialised small company (Rotomed AG, Allmenstrasse 4, CH-4512 Bellach, www.rotomed.ch) based on the principles of Ilizarov's external fixator. In all patients, subjective and objective results were satisfactory (26.2 mm distraction length and an average Michigan Hand Outcome Score of 82.2%) without any rotational/axial deformities or complications requiring revision surgery.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.