Abstract

BACKGROUNDHypercoagulability plays an important role in predisposing patients to venous thromboembolism (VTE) after total hip arthroplasty (THA). We used thromboelastography (TEG) to examine the coagulation status of patients undergoing THA.AIMTo examine coagulation as measured by TEG in patients undergoing THA who received standard VTE chemoprophylaxis with enoxaparin. METHODSAfter ethical approval, we performed a retrospective analysis of data collected in patients undergoing primary elective THA. We analyzed TEG data on samples performed before skin incision, intraoperatively and for 5 d postoperatively. Conventional coagulation tests were performed preoperatively and on postoperative day 5. RESULTSTwenty patients undergoing general anesthesia and 32 patients undergoing spinal anesthesia (SA) were included. TEG demonstrated a progressively hypercoagulable state postoperatively, characterized by elevated maximum amplitude. TEG also demonstrated transient intraoperative hypercoagulability in patients receiving SA. In contrast, conventional coagulation tests were normal in all patients, pre- and postoperatively, except for an increase in plasma fibrinogen day 5 postoperatively. CONCLUSIONDespite VTE prophylaxis, patients following total hip replacement remain in a hypercoagulable state as measured by both TEG and conventional tests. This group may benefit from more optimal anticoagulation and/or additional perioperative hemostatic monitoring, via TEG or otherwise.