BackgroundLow volume resuscitation (LVR) in shock prevents deleterious effects of crystalloid loading in pre-hospital settings. Polyethylene glycol 20,000 (PEG-20k) based LVR solutions are 20-fold more effective at maintaining perfusion and survival in shock compared to conventional crystalloids. The aim of this study was to determine coagulation and platelet function of whole blood treated with 10% PEG-20k.MethodsCitrated blood from volunteers (n = 25) or early admission severely injured trauma patients (n = 9) were diluted 10% with various LVR solutions in a matched design with a paired volume control (saline), and studied using thromboelastography (TEG).FindingsIn healthy volunteers and patients, 10% PEG-20k significantly increased clot amplification time (k), decreased propagation (angle), maximal clot size and strength (MA), and the overall coagulation index (CI), but not clot initiation (R) or fibrinolysis (Ly30), relative to paired saline dilutional controls. Clinically, K, angle, and MA were just outside of the normal limits in volunteers but not in patients. No statistical differences existed between PEG-20k and Hextend (HES) in either patient population. In a dose response series using volunteer blood, all effects of 10% PEG-20k on TEG were reversed and normalized by lower concentrations (7.5% and 5%). Furthermore, 7.5% PEG-20k produced similar resuscitation effects as 10% PEG in rodent hemorrhagic shock models (n = 5).ConclusionsIn conclusion, PEG-20k based LVR solutions produced a dose-dependent minor hypocoagulative state, possibly associated with changes in clot propagation and platelet function, which can be reversed by dose reduction in concentration while providing superior LVR, microvascular rescue, and lactate clearance compared to saline or starch.

Highlights

  • Minimizing the use of crystalloids and utilizing blood products after trauma are becoming mainstream in civilian trauma centers

  • Polyethylene glycol 20 (PEG-20k) based Low volume resuscitation (LVR) solutions produced a dose-dependent minor hypocoagulative state, possibly associated with changes in clot propagation and platelet function, which can be reversed by dose reduction in concentration while providing superior LVR, microvascular rescue, and lactate clearance compared to saline or starch

  • Normal saline (0.9% NaCl, NS; prepared using 9 g/L sodium chloride) served as both a crystalloid vehicle volume control, and as a dilutional volume control [1, 2]

Read more

Summary

Introduction

Minimizing the use of crystalloids and utilizing blood products after trauma are becoming mainstream in civilian trauma centers. Crystalloid resuscitation exacerbates TICS, acidosis, hypothermia, and coagulopathy [3, 4]. Other resuscitation solutions such as hypertonic saline or starch have had disappointing results [5, 6] including concerns and risks associated with their use [4, 7]. Low volume resuscitation (LVR) in shock prevents deleterious effects of crystalloid loading in pre-hospital settings. Polyethylene glycol 20,000 (PEG-20k) based LVR solutions are 20fold more effective at maintaining perfusion and survival in shock compared to conventional crystalloids. The aim of this study was to determine coagulation and platelet function of whole blood treated with 10% PEG-20k

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.