Abstract

IntroductionThe incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR.MethodsThe data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017.ResultsCardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A.ConclusionThe implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.

Highlights

  • The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear

  • Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018)

  • The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements

Read more

Summary

Introduction

The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. Surgical aortic valve replacement (AVR) still represents the gold standard in patients with severe aortic valve stenosis[1]. Owing to increasing age of the patient population in the Western world, there has been an increase in the prevalence of patients with valvular heart disease eligible for AVR[2]. Given the increasing number of co-morbidities and the increasing age of patients, a tendency has emerged to use biological valve implants avoiding the need for long-term anticoagulation therapy. The concept of transcatheter aortic valve implantation (TAVI) appears attractive, the calcified aortic valve is not removed during this procedure. Paravalvular leakage remains an important issue with this technique[3]. Other important concerns are access site-related problems and device malpositioning

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.